Regenair® Regenerative Blowers

Regenair regenerative blowers

Table of Contents

Regenair regenerative blowers

          Regenair regenerative blowers are a type of industrial blower that uses a unique operating principle to move air or other gases. These blowers are designed to deliver high volume, low-pressure airflow, and are commonly used in applications such as wastewater treatment, pneumatic conveying, vacuum lifting, and other industrial processes that require the movement of air or gas.

          Regenair® blowers work by utilizing the regenerative principle, which involves a spinning impeller that generates a high-velocity airflow that is directed into a stationary stator. As the air passes through the stator, it is redirected back into the impeller, where it is compressed and forced out through the discharge port. This cycle of compression and expansion creates a continuous flow of air or gas.

          One of the main advantages of Regenair® blowers is their efficiency. They are able to achieve high flow rates with relatively low power consumption, making them an energy-efficient option for many industrial applications. They are also compact, durable, and require minimal maintenance, making them a popular choice for a wide range of industries.

          Overall, Regenair® regenerative blowers are a reliable and cost-effective solution for many industrial applications that require the movement of air or gas.

Regenair regenerative blowers

Why use a Regenair ® Regenerative Blower?

Features and Benefits

Standard Motor Mounted Models
  • Rugged construction of cast aluminum or cast iron, depending on model size
  • UL and CSA approved motors; TEFC on single-
    ended models, OPEN on dual-ended models.
    Permanently sealed ball bearings incorporate new
    polyurea grease that extends bearing life and offers
    superior resistance to washout, rust, and corrosion.
    Integrated mufflers on single-ended models
    minimize operating noise
Explosion-Proof Motor Series
  • UL and CSA approved explosion-proof multi-voltage motors with thermal protection
  • Double sealed ball bearings with a B10 life exceeding 30,000 hours of continuous operation at the maximum rated continuous blower load
  • Sealed air streams; leak tested to less than 5 cc/min
Separate Drive Series
  • Drive pulley size can be changed to lower speeds and adjust performance
  • Built-in acoustical muffling reduces operation noise
  • Precision balanced impellers provide low vibration operation

The Regenerative Principle

In a regenerative blower, the compression space consists of a hollow,
circular ring between the tips of the impeller blades and the walls of the
housing. In operation, the rotating impeller draws in air from the inlet
port into the compression space and moves it radially outward to the
curved housing by centrifugal force.
The action is called “regenerative” because a certain amount of air
slips past each impeller blade during rotation and returns to the base
of a succeeding blade for reacceleration.
Because of this dynamic principle, regenerative blowers can generate
pressure and vacuum performance comparable to many multi-stage or
positive displacement blowers.

Regenair ® Regenerative Blowers Performance Overview

MODEL/
SERIES
POWER RATING
@ 60 Hz
FREE AIR FLOW MAXIMUM PRESSURE MAXIMUM VACUUM
CFM M³/h inH₂O mbar inH₂O mbar
HP Kw 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz
Standard Motor Mounted Models
R1* ¹/₈ 0,09 23 27 39 46 21 28.5 52 71 20 26.5 50 66
R2* ¹/₃ ,¹/₂ 0,25,0,37 33 42 56 71 30 39 75 97 25 35 62 87
R3* ¹/₂ 0,37 43-44 52-53 73-75 88-90 31-40 43-55 77-100 107-137 28-35 40-50 70-87 100-125
R4* 1 0,75 75 92 127 156 38 52 95 130 35 45 87 120
R4P* 1¹/₂ 1,1 110 127 187 216 50 65 125 162 45 60 112 149
R5* 2¹/₂ 1,86 133 160 226 272 50 65 125 162 47 60 117 149
R6* 2¹/₂-
5
1,86-
3,73
180 207-
215
306 352-
365
40-
78
45-
105
100-
194
112-
262
50-
70
55-
88
125-
194
137-
262
R6P* 3¹/₂-
5¹/₂
2,6-
4,1
225-
245
265-
290
382-
416
450-
493
50-
85
30-
110
125-
212
75-
274
50-
85
35-
90
126-
212
87-
224
R6PP* 11 8,2 420 520 714 884 75 95 187 237 65 80 162 199
R7* 10 7,46 350 420 595 714 115 125 286 311 90 110 224 274
R7P* 18 13,4 666 795 1132 1351 90 105 284 262 85 95 212 237
R9* 15 11,3 585 680 994 1155 125 125 311 311 105 115 262 286
R9P* 30 22,4 1140 1350 1937 2294 110 125 274 311 100 110 249 274
High Pressure Motor Mounted Models
R4H*   6 4,5 107 128 182 217 284 284 707 707 183 183 456 456
R6PS*  11 8,2 230 280 391 476 145 170 261 423 110 130 274 324
R7S*  18 13,4 350 420 595 714 170 200 423 498 130 150 324 374
R9S*  30 22,4 585 660 994 1121 208 222 518 553 142 149 354 371
Explosion Proof Motor Models
R3105N-50  ¹/₂ 0,37 44 53 75 90 31 43 77 107 28 40 70 100
R4110N-50  1 0,75 74 92 126 156 38 51 95 127 35 48 87 120
R4310P-50  1 0,75 74 92 126 156 38 51 95 127 35 48 87 120
R4P115N-50  1¹/₂ 1,1 112 133 190 226 45 65 112 162 40 60 100 149
R5125Q-50  2 1,5  - 160  - 272  - 55  - 137  - 60  - 149
R5325R-50  2 1,5 133 160 226 272 50 65 125 162 47 65 117 162
R6130Q-50  3 2,2 180 215 306 365 75 60 187 149 65 70 162 174
R6340R-50  4 3,0 180 215 306 365 75 100 187 249 65 80 162 199
R6P155Q-50  5¹/₂ 4,1 280 280 399 476 80 95 199 237 65 85 162 212
R6P355R-50  6 4,5 280 280 394 476 80 100 199 249 65 85 162 212
R7100R-50  10 7,5 425 425 595 722 90 100 224 249 85 110 212 274
Separate Drive Models
SDR4  4 3,0 147 250 110 274 90 224
SDR5  10 7,5 240 408 152 379 120 299
SDR6  15 11,2 300 510 155 386 135 336

*Models equipped with UL and CSA certified motors. (except R1102K (12v DC))

Catalog Performance Specifications

The specifications listed are that of a unit at sea level with an ambient temperature of 70 °F (21 °C), operating with normal electrical current conditions. The figures stated in this catalog are nominal approximations for models without accessories. Intake filters and exhaust mufflers, and the accumulation of contaminants in them during operation, will decrease the flow of air as well as the achievable pressure. The units that we list in this catalog are a small portion of what we actually make. Those listed are considered “standard units” and are normally available from stock in small quantities. Variations are produced for many customers and by informing us of the application specifications we might find an existing unit that fits your requirement. If we don’t and the quantity is sufficient, we will design a “special unit” for the application. Pictorial and dimensional data is subject to change without notice.

Blower System Design Tips

In order to utilize your regenerative blower most efficiently, proper system design is essential. The most important thing to recognize is that by utilizing large diameter plumbing, friction losses in plumbing can be greatly reduced. Here are some guidelines to use when setting up your blower system:

1. The plumbing should at least be the same size as the blower port or ideally one size larger (example – blower has ports that are 1-1/2” NPT, plumbing should be 2” NPT). The plumbing should remain this size until it has reached the location of the work area.

2. Plumbing for Separate Drive Blowers operating above 3500 RPM should be at least one pipe size larger than the blower ports.

3. Elbows create additional friction, which causes pressure loss and back pressure. Plumbing at least one pipe size larger than the blower pipe ports minimizes the friction loss they create.

4. The pressure/vacuum relief valve should be installed in a “T” which is at least one pipe size larger than that of the exhaust of the blower. To properly protect a large horsepower blower, set the relief value to limit the blowers duty to 5 in H₂O below its continuous duty rating.

5. Operating the blowers at high altitude decreases their maximum pressure or vacuum duty rating. If this is a consideration, review the information on Fan Laws in the Application Engineering section of this catalog.

6. The exhaust air temperature of the blowers increases with increasing duty. At duties over 70 in H₂ it is too hot for most plastic pipe. Metal pipe must be considered. To prevent danger of burns, access to these pipes should be limited, guarded, or marked “Danger Hot.”

Performance Data

The performance data shown in this catalog was determined under the following conditions:

  • Line voltage @ 60 Hz 230V or 460V for three-phase units. 
  • 115V or 230V for single-phase units.
  • Line voltage @ 50Hz 220V for three-phase or single – phase units.
  • Units in a temperature stable condition.
  • Delivery measurements made with output port throttled.
  • Suction measurements made with input port throttled.
  • Test Conditions: Inlet air density at 0.075 lbs per cu ft.
  • [20 °C (68 °F), 29.92 inHg (14.7 PSIA)].
  • Normal performance variations on the resistance curve within ± 10% of supplied data can be expected.

Typical Applications – Imagine what you can do with air, then call Gast

We offer cost-effective solutions to blower applications for both OEMs and end-users. Gast’s Regenerative Blower line of products are designed and built to meet the changing needs of industry and are ideally suited for a number of blower applications. These are ex-amples of many applications where Gast’s Regenerative Blowers are widely used.

PRESSURE APPLICATIOS

Bag Packaging Equipment

Vacuum is often used to open,
hold, and close bags in filling machines.

Vacuum Conveying

Plastic pellets, grain, powder, and other bulk dry materials can be transported from one container to another easily using vacuum. They are pulled into a transport tube and delivered to a separator before being deposited
in the final storage container.

Pond Aeration

Pond aeration is done for two basic reasons. One is aquaculture, where large numbers of fish are “farmed” in a single pond. The second is ecological.
As a pond or lake ages, it can lose its oxygen supply and may die. When air is introduced into a pond or lake, oxygen becomes plentiful again and life in and around the water can flourish.

Paper Stack Air Table
The stacks of paper in all graphic arts applications are extremely heavy. To make matters more difficult, the combination of high speed presses and the various types of paper make it necessary to handle these stacks frequently. To make the job easier, these stacks are floated on an air table so they can be manipulated with very little effort.
Agricultural equipment
  • Aquaculture/pond aeration
  • Fish hatchery equipment
Transportation equipment
  • Suspension systems, tire inflators
Medical equipment
  • Medical and dental sterilizing equipment
  • Dental vacuum ovens, dental aspiration
Industrial tools and machinery
  • Fiberglass choppers
  • Liquid/hydraulic pump drives
  • Industrial cleaning equipment
  • Chip removal/parts blow off
  • Engraving machinery
Material handling equipment
  • Lift tables
  • Pneumatic conveying systems and drives
  • Automated assembly machines/robotics
Computer, business, office machines, and equipment
  • Envelope opening/inserting/labeling equipment
  • Document scanning equipment
Graphic arts equipment
  • Folders, presses, counters
  • Photo processing equipment
  • Corrugated cutting/printing equipment
  • Ink jet printer/post press printing equipment
  • Collating/inserting equipment
  • Ink drying equipment
  • Air table
Sports and leisure equipment
  • Spa and hot tub aeration, aquarium aeration
  • Handicap tub door seals, boat/pond deicing
Food, drug, and chemical equipment
  • Ice cream/yogurt/frosting dispensers
  • Pharmaceutical manufacturing equipment
  • Automated food preparation equipment
Electronics and communications equipment
  • Cable pressurization/cable slicing equipment
  • Circuit board processing equipment
Environment, pollution, and safety equipment
  • Air/water purifiers
  • Gas generators (ozone, nitrogen)
  • Sewage treatment
  • Smoke evacuation
  • Pest control equipment
  • Soil/groundwater remediation equipment
Packaging equipment
  • Marking/labeling equipment
  • Filling equipment
  • Food packaging/bag making equipment
  • Can/bottle making equipment
  • Liquid packaging equipment
  • Corrugated sheet making equipment
Textile industry equipment
  • Sewing machine equipment, scrap collection equipment
Processing equipment
  • Mixing equipment
  • Vibrators/tumblers
  • Plating tank agitation
  • Laundry equipment
  • Forming equipment
  • Parts washers/parts drying equipment/air knives
  • Plastic pellet drying/conveying
Energy equipment
  • Oil atomization, industrial burners
Mining and construction equipment
  • Texture spraying, concrete aeration

VACUUM APPLICATIONS

Vacuum Holding of Automated Cutting
Lasers, water jets, and knives are all precision tools for cutting a wide variety of materials automatically. These computers driven machines use vacuum to hold materials being cut in place.
Automated Product Feeding

Vacuum force is used to automatically stack product as it is received or to move the product from one process to another.

Soil Vapor Extraction
Contaminated soil is often treated by pulling the contaminants, usually gasoline or other hydrocarbons, out of the soil with vacuum.
Dust and Chip Collection
Vacuum power is used to collect dust and/or chips from saws, mills, and other cutting machines.
Home Aerobic Sewage Treatment

Some parts of the country where city sewerage is not available and high water tables exist, household waste must be treated aerobically. This means air is mixed into a solution which activates microbes that feed on the waste, speeding up the naturally occurring organic breakdown.

Agricultural equipment
  • Inoculation equipment
Medical equipment
  • Dental vacuum ovens, dental aspiration
Industrial tools and machinery
  • Gas reclaiming equipment
  • House air/vacuum
  • Industrial vacuum systems
  • Industrial cleaning equipment
  • Vacuum table/hold down
  • Dust collection equipment
  • Chip removal
  • Engraving machinery
Material handling equipmen
  • Vacuum hoist
  • Pneumatic conveying systems
  • Pneumatic tube systems
  • Automated assembly machines
Computer, business, office machines, and equipment
  • Envelope opening/inserting/labeling equipment
  • Vacuum feed, document scanning equipment
Graphic arts equipment
  • Folders, presses
  • Vacuum frames
  • Photo processing equipment
  • Paper counters
  • Camera/exposure equipment
  • Corrugated cutting/printing equipment
  • Collating equipment
  • Inserting equipment
  • Post press printing equipment
Food, drug, and chemical equipment
  • Pharmaceutical manufacturing equipment
  • Automated food preparation equipment
  • Electronics and communications equipment
  • Circuit board processing equipment
  • Cable splicing equipment
Environment, pollution, and safety equipment
  • Air sampling/monitoring equipment
  • Toilet systems
  • Fume extraction
  • Vapor recovery
  • Smoke evacuation
  • Pest control equipment
  • Soil vapor extraction
  • Weather prediction equipment
Packaging equipment
  • Case erectors/packers
  • Marking/labeling equipment
  • Bag making equipment
  • Filling equipment
  • Food packaging equipment
  • Can/bottle making equipment
  • Liquid packaging equipment
  • Corrugated sheet making equipment
  • Packing fill removal equipment
Textile industry equipment
  • Sewing machine equipment
  • Scrap collection equipment
  • Garment vacuum tables
  • Trim removal
Processing equipment
  • Vibrators/tumblers, non-medical lab equipment
  • Forming equipment, plastic pellet drying/conveying

Performance Curves REGENAIR ® Regenerative Blowers

Performance Curves – Low Range for Pressure/Vacuum
Motor mounted series R1, R2, R3, R4, R4P, R5
Performance at 60 Hz

Gast advertises blower performance in Free Air Flow, or air subjected to only atmospheric pressure. (See above curves) Some blower manufacturers advertise vacuum performance in CFm Inlet Air – measurement of the suction of air at a specific temperature at the inlet port and a specific discharge pressure at the exhaust port, which can be perceived as enhanced performance over Free Air Flow rated blowers. Therefore, we are also providing the following vacuum performance for Gast blowers in CFm Inlet Air for comparison to other blower manufacturer’s advertising.

Performance Curves REGENAIR ® Regenerative Blowers

Performance Curves – Mid Range for Pressure/Vacuum
Motor mounted series R6, R6P, R6PP, R7, R7P, R9, R9
Performance at 60 Hz

Gast advertises blower performance in Free Air Flow, or air subjected to only atmospheric pressure. (See above curves) Some blower manufacturers advertise vacuum performance in CFm Inlet Air – measurement of the suction of air at a specific temperature at the inlet port and a specific discharge pressure at the exhaust port, which can be perceived as enhanced performance over Free Air Flow rated blowers. Therefore, we are also providing the following vacuum performance for Gast blowers in CFm Inlet Air for comparison to other blower manufacturer’s advertising.

Performance Curves REGENAIR ® Regenerative Blowers

Performance Curves – High Range for Pressure/Vacuum
Motor mounted series R4H, R4H-1, R6PS, R7S, R9S
Performance at 60 Hz

Gast advertises blower performance in Free Air Flow, or air subjected to only atmospheric pressure. (See above curves) Some blower manufacturers advertise vacuum performance in CFm Inlet Air – measurement of the suction of air at a specific temperature at the inlet port and a specific discharge pressure at the exhaust port, which can be perceived as enhanced performance over Free Air Flow rated blowers. Therefore, we are also providing the following vacuum performance for Gast blowers in CFm Inlet Air for comparison to other blower manufacturer’s advertising.

Envelope Dimensions REGENAIR ® Regenerative Blowers

Model #   Net Wt.
(lbs)
A Length
(inches)
B Width
(inches)
C Height
(inches)
Inlet/Outlet
Connections
STANDARD MOTOR MOUNTED
R1102 16 8.86 7.80 8.51 1''
R1102C  16 8.86 7.80 8.51 1''
R1102K  16 9.21 7.80 8.51 1''
R2103  21 9.90 8.93 9.29 1''
R2105  23 10.57 8.93 9.29 1''
R2303A  23 9.90 8.93 9.29 1''
R2305B  23 10.85 8.93 9.29 1''
R3105-1  29 10.94 9.72 10.15 1¹/₄''
R3105-12  29 10.94 9.72 10.15 1¹/₄''
R3305A-1 29 10.94 9.72 10.15 1¹/₄''
R3305A-13 29 10.94 9.72 10.15 1¹/₄''
R4110-2  41 12.82 11.25 11.80 1¹/₂''
R4310A-2  41 12.82 11.25 11.80 1¹/₂''
R4310B-1  41 12.82 11.25 11.80 1¹/₂''
R4P115  61 15.46 13.26 13.61 1¹/₂''
R4P315A 43 11.38 13.26 13.61 1¹/₂''
R5125-2 76 16.14 13.56 13.80 1¹/₂''
R5325A-2  65 15.23 13.56 13.80 1¹/₂''
R5325B-1  65 14.73 13.56 13.80 1¹/₂''
R6125-2  87 16.45 15.17 15.38 2"
R6325A-2  76 15.53 15.17 15.38 2"
R6135J-10 112 15.86 15.17 15.38 2"
R6335A-2 82 16.59 15.17 15.38 2"
R6335B  82 16.00 15.17 15.38 2"
R6150J-2  125 17.46 15.17 15.38 2"
R6350A-2 112 17.35 15.17 15.38 2"
R6350B-2 112 17.35 15.17 15.38 2"
R6P335A 150 16.69 16.75 18.15 2"
R6P350A 176 17.75 16.75 18.15 2"
R6P350B 176 17.75 16.75 18.15 2"
R6P355A  215 19.92 16.75 18.15 2"
R6PP3110M 309 23.19 16.75* 18.21 2"/3''
R7100A-3  293 22.58 18.00 20.03 2¹/₂''
R7100B-1  290 21.58 18.00 20.03 2¹/₂''
R7P3180M 438 28.47 18.00* 20.12 2¹/₂''/4''
R93150A 452 26.13 20.63 22.63 3''
R9P3300M 622 32.78 20.63* 22.54 3''/5''
HIGH PRESSURE MODELS 
R4H3060A  200 21.47 16.90 18.82 2"
R4H3060A-1 200 21.47 16.90 18.82 2"
R6PS3110M  309 23.19 16.75 18.21 2"
R7S3180M  431 28.47 18.00 20.12 2¹/₂''
R9S3300M  606 32.78 20.63* 22.54 3''
EXPLOSION PROOF MOTOR MODELS
R3105N-50 52 12.3 12.75 10.15 1¹/₄''
R4110N-50 60 15.34 12.34 11.80 1¹/₂''
R4310P-50 58 14.09 12.34 11.80 1¹/₂''
R4P115N-50  79 17.41 13.75 13.61 1¹/₂''
R5125Q-50 77 17.59 13.72 13.80 1¹/₂''
R5325R-50 75 16.75 13.56 13.80 1¹/₂''
R6130Q-50  129 18.97 15.17 15.34 2"
R6340R-50 112 18.82 15.17 15.31 2"
R6P155Q-50 243 22.81 16.75 18.14 2"
R6P355R-50          
R7100R-50 297 22.77 18.00 20.03 2¹/₂''
SEPARATE DRIVE MODELS
SDR4  27 12.44 11.25 11.80 1¹/₂''
SDR5 37 14.22 13.56 13.78 1¹/₂''
SDR6 70 15.89 15.17 15.31 2''

*Less muffler(s)

BASIC STYLE

R1, R2, R3, R4, R4H, R4P, R5, R6, R6P, R7, R9

STAGED
R6PS, R7S, R9S
PARALLEL
R6PP, R7P, R9P
SEPARATE DRIVE
SDR4, SDR5, SDR6
EXPLOSION PROOF MOTOR MODELS

R3, R4, R4P, R5, R6, R6P, R7

Accessories REGENAIR ® Regenerative Blowers

Mufflers

Designed to reduce noise by 5-8 dBa and remove high frequency sound associated with all blowers.
Part No. Dim. A Dim. B Dim. C Used On
AJ121B 7.46'' 2.38'' 1'' NPT R1, R2
AJ121C 7.94'' 2.62'' 1¹/₄'' NPT R3
AJ121D 12.75'' 3.25'' 1¹/₂'' NPT R4, R5, R4P, R4H, R7
AJ121F 17.05'' 3.63'' 2'' NPT R4H, R6, R6P, R6PP, R6PS
AJ121G 17.44'' 4.25'' 2¹/₂'' NPT R7, R7P, R7S
AJ121H 20.25'' 4.75'' 3'' NPT R6PP (Exhaust), R9, R9P, R9S
AJ121M 33.50'' 6.00'' 4'' NPT R7P (Exhaust)

Pressure-Vacuum Gauge

To monitor the system performance so maximum duties are not exceeded. Using two gauges (one on each side of the filter) is a great way to know when the filter needs servicing.
Part No. Used On
AJ497 Vacuum gauge 0-60 inH₂O, 1/4'' NPT connection  R1, R2, R3, R4 R4H, R4P, R5, R7, R7P, R7S, R9, R9P, R9S
AE134 Vacuum gauge 0-160 inH₂O, 1/4” NPT connection  R4P, R6PP, R6PS, R6P, R4M, R6, R7, R7S, R7P, R9, R9P, R9S
AE134F Vacuum gauge 0-15 inHg, 1/4” NPT connection  R4H,
AE133 Pressure gauge 0-160 inH₂O, 1/4” NPT connection R6PP, R6P, R5, R4P, R6, R7P, R9, R9P
AE133A Pressure gauge 0-200 inH₂O, 1/4” NPT connection R6PS, R7, R7S
AE133F Pressure gauge 0-15 psi, 1/4” NPT connection  R4H, R9S
AJ496 Pressure gauge 0-60 inH₂O, 1/4” NPT connection  R1, R2, R3, R4

Check Valve

Designed to prevent back-wash of fluids that would enter the blower. Also prevents air back-streaming if needed. Can be mounted with discharge either vertical or horizontal. Valve will open with 3” of water pressure.
Part No. Dim. A Dim. B Dim. C
AH326B 3.57'' 2.32'' 1'' NPT
AH326C 4.19'' 2.69'' 1¹/₄'' NPT
AH326D 4.50'' 2.94'' 1¹¯/₄'' NPT
AH326F 5.25'' 3.82'' 2'' NPT

Relief Valve

By setting a relief valve at a given pressure/vacuum, you can ensure excessive duties will not harm the blower or products in your application.

Part No. Used On
AG258 Relief Valve  1-1/2''  NPT adjustable 30-200 inH₂O, vac. or press., 200 CFM max. 
AG258F Relief Valve  2-1/2” NPT adjustable 25-200 inH₂Os, vacuum or pressure, 570 CFM 
PV102 Relief Valve  For pressure, pre-set for 10.2 psi, 1-1/4'' NPT connection (60 Hz) 

Filters

Inlet filters (for pressure)

Part No.   Dim. A   Dim. B   Dim. C   Filter Replacement   Used On
AJ126B   6.00'' 4.62'' 1'' MPT AJ134B (10 micron)   R1, R2
AJ126C   6.00'' 7.12'' 1¹/₄'' MPT AJ134C (10 micron)   R3
AJ126D   7.70'' 7.25'' 1¹/₂'' MPT AJ134E (10 micron)   R4, R4H, R4P, R5
AJ126F   10.63'' 4.81''  2'' MPT AG340 (10 micron)   R6, R6P, R6PS, R6PP, R9
AJ126G   10.00'' 13.12'' 2¹/₂'' MPT AJ135A (10 micron)  R7, R7P,
AJ126L   10.00''  14.62'' 4'' MPT AJ135C (10 micron) Consult factory
AJ126M   16.00'' 14.62'' 5'' MPT AJ135H (10 micron)   Consult factory

MPT = male Pipe Thread. FPT = Female Pipe Thread. All are heavy-duty for high amounts of particulates.
Inlet filters for REGE nAIR ® blowers are drip-proof when mounted as shown.

Filters

In locations where there are high amounts of dust, powder, or dirt suspended in the air, inline filters (for vacuum applica – tions) and inlet filters
(pressure applications), should be used. Keeping particulates from entering the blower will ensure smooth operation and trouble free service life.

Inline filters (for vacuum)

AV series

Part No. Dim. A Dim. B Dim. C Dim. D Used On
AV460 8¹/₄'' 8⁷/₈'' 1'' FPT 1'' FPT R1, R2
AV460C 8¹/₄'' 8⁷/₈'' 1¹/₄'' FPT 1¹/₄'' FPT R3

Replacement elements for AV460 and AV460C:
AV463A - Cloth bag, 50 micron, sold in 3 pack (letter F on diagram).
AV469A - Paper filter, 5-10 micron, sold in 12 pack (letter E on diagram).

AJ series

Part No. Dim. A Dim. B Dim. C Dim. D Dim.E Filter Replacement Used On
AJ151A 5.88'' 4.50'' 2.75'' 1'' FPT  1'' FPT AJ135D (10 micron) R1
AJ151B 7.38'' 6.81''  4.62'' 1'' FPT 1'' FPT AJ135E (10 micron) R2
AJ151C  7.38''  6.81'' 4.62'' 1¹/₄'' FPT 1¹/₄'' FPT AJ135E (10 micron) R3
AJ151D  7.38''  6.81'' 4.62'' 1¹/₂'' FPT 1¹/₂'' FPT AJ135E (10 micron) R4, R4P
AJ151E 8.75'' 10.25'' 5.00'' 2'' FPT 2'' FPT AJ135F (10 micron) R4H, R4P, R5
AJ151G 8.75'' 10.50'' 5.50'' 2¹/₂'' FPT 2¹/₂'' FPT AJ135G (10 micron)  R6, R6P
AJ151H 14.00'' 27.13'' 18.50'' 3'' MPT 3'' MPT AJ135C (10 micron) R6PP, R6PS, R7
AJ151M 18.50'' 28.13'' 19.50'' 5'' MPT 5'' MPT AJ135H (10 micron) R7P, R7S, R9, R9P, R9S

mPT = male Pipe Thread. FPT = Female Pipe Thread. All are heavy-duty for high amounts of particulates.
Inline filters for REGE nAIR ® blowers are drip-proof when mounted as shown.

Regenair ® Filter Restrictions with Clean Element

Inlet Filters

 Blower   Filter Restriction in
inH₂O at CFM Flow
Indicated
R1 AJ126B 2.2'' @ 27 CFM
R2 AJ126B 4.5'' @ 40 CFM
R3 AJ126C 2.5'' @ 50 CFM
R4H AJ126D 8'' @ 120 CFM
R4 AJ126D 4'' @ 85 CFM
R4P AJ126D 8'' @ 120 CFM
R5 AJ126D 11'' @ 146 CFM
R6 AJ126F 7'' @ 200 CFM
R6P/R6PS AJ126F 11'' @ 265 CFM
R6PP (2) AJ126F 10'' @ 240 CFM
R7/R7S AJ126G 12'' @ 400 CFM
R7P (2) AJ126G 12'' @ 400 CFM
R9S AJ126M Consult factory
R9P AJ126M Consult factory

Inlet Filters

Blower
Size
Filter
Number
Restriction in
inH₂O at CFM Flow
Indicated
R1 AJ151A 1'' @ 25 CFM
AV460 2'' @ 25 CFM
R2 AJ151B 2'' @ 40 CFM
AV460 5'' @ 40 CFM
R3 AJ151C 2'' @ 50 CFM
AV460C 3'' @ 50 CFM
R4 AJ151D 3'' @ 100 CFM
R4P AJ151E 3'' @ 100 CFM
R4H AJ151E 3'' @ 120 CFM
R5 AJ151E 4'' @ 160 CFM
R6 AJ151G 2'' @ 200 CFM
R6P/R6PS AJ151G 3'' @ 300 CFM
6PP AJ151H 8'' @ 400 CFM
R9S AJ151 M Consult factory
R9P AJ151 M Consult factory